Model

CA50

Picture

Waste Treatment

Waste Incineration Treatment

Feed Capacity

Average 50 kgs per feed

Burning Rate

Average 100 kgs per hour

Burning Time per Feed

Average 2 hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Voltage

220V

Power

0.7Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Temperature Monitor

Digital Display

Fuel consumption (Oil)

Average 16.6 Kgs/Hour

Internal Dimensions

100x80x70cm (Primary Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Post Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Chimney

5.0M

Gross Weight

4500kgs

Chamber Material

Firebrick ,Refractory Concrete

Max. Heat Value

166,000Kcal/Hr.

Operation Technical Specifications

Solid Chamber temperature

8000C -10000C

Gas Chamber temperature

10000C -12000C

Chamber Anti-Rate

14500C

Residency time

2.0 Sec.

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal

Syringes/Needles/Sharps.The supplier shall be able to provide and replace all below 
mentioned major spare parts for a period of 5 years (from delivery), at their own cost.
o. primary and secondary chambers shall preferably have rounded inside corners to 
avoid the formation of dead zones or cold pockets
Multiple electric ignition fuel burners designed to use automotive diesel fuel.
• Flame of the primary burner shall be oriented towards the center of the unit which 
does not impinge directly on the refractory floor or wall. The secondary burner shall be 
positioned in such a way that the flue gas passes through the flame. 
• The unit shall prevent leakage of the hot flue gas and any backfire. 
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• Digital thermometers connected to electronic dataloggers. The thermometers shall be located 
on the chamber walls away from the fuel burner.
• A differential air pressure gauge connected to an electronic datalogger

The secondary chamber must comply with the following minimum criteria:
a. be based on common, well-proven and clean technology – both as a complete unit and in
terms of its individual components.
Fuel Fillers
Blast Tubes
Nozzles
Diffusers
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank), 
The proposed incinerator units must be complete and include all of the key features listed 
below and all of the associated support services and interconnections
The forecasted feedstock loads, and daily loading rates are generally summarized as:
• Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values 
and densities.   The wastes will consist of 100% biomedical wastes.
• Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size.
• Operation on a daytime shift basis, 5 days per week.
“• Minimum load capacity: 20 kg
• Maximum load capacity: 40 kg
• Nominal burning rate: 10-30 kg/hr (= 80- 240 kg range per 8hour day)

10 – 15mm Steel casing
high grade paint finish
Light weight resilient refractory fiber insulation door for thermal efficiency
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%.
Surgery waste
A heat exchanger to pre-heat air destined for the primary chamber is not compulsory 
but recommended. 
The combustion air systems and fans shall be designed to ensure high combustion efficiency 
and avoid a reducing (corrosive) atmosphere, incomplete burnout of the flue gases and related 
problems. It should also be possible to heat the
“Each unit shall include a complete vertical exhaust and stack system, including the following features:
• Steel construction.
• Refractory lining in the lower section.
• The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending on the capacity of the incinerator unit. 
• The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity 
of not less than 10 metres per second vertically upwards when at full scale operation.
• An emission stack sampling port shall be included immediately above the secondary chamber.