This model is small-scale waste incineration equipment for small waste output. 
Construction is dual/double combustion chamber with 02 units oil burner, 
batch load incineration equipment. Waste feed chamber is 2000Liters (2.0m3, TS300 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the 
bottom of chamber. Incinerator PLC panel control suit for local operation.
WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  

Items/Model

TS300(PLC)

Principle

Medical Waste Incineration Treatment

Burn Rate

Average 300 kg/hour

Feed Capacity

Average 400kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2000L

Internal Dimensions

170x120x100cm

Secondary Chamber

1000L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

2.0Kw

Oil Consumption (kg/hour)

Average 38(DO)

Gas Consumption (m3/hour)

Average 45.6(NG)

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

500L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

11000kg

External Dimensions

400x210x300cm(without chimney)

“Waste chamber
Chamber capacity 300 kg
Chamber volume .54m3
Chamber size (outside) Width: 91cm, Height: 86cm Length: 152cm
Door opening 66 x 76 cm
Height to door 84 cm
Height to top of stack 5.4 m
Suggested slab size (L x W x Thickness) 1.8 m x 2.4 m x 10 cm
Burn rate: Approximately 45 kg/hr.
Stack:
2′-14″” dia. (36 cm), 14 gauge (1.90 mm) aluminized steel, refractory lined
8′-12″” dia. (30.5 cm), 16 gauge (1.52″
“Burners Diesel
Operation Manual timer
Electrical service Standard – 115 volt, 60 HZ, 20 amp
General Description:
Primary Chamber: Heavy-duty steel casing
High quality refractory lining and insulation
Large full size top load door and liquid retention sill
1 x diesel oil fired ignition burners operated on/off
Ash removal door
Chimney: Heavy-duty stainless steel casing
1.5m length
0.6m refractory lined stack
Control Panel: Control of 1 burner
Timer control 0-12 hours
Integral fan timer control
Temperature monitoring
Automatic Control
Cycle time set up
Ancillaries: Operating and maintenance manuals
Spares list
Ash Rake
Containerization: 20 foot shipping container with incinerator fitted
500 litre fuel tank”