Incinerator Model TS100M, Overview

This model is small-scale waste incineration equipment for small waste output. 
Construction is dual/double combustion chamber with 02 units oil burner, batch 
load incineration equipment. Waste feed chamber is 560Liters (0.56m3, TS100M). 
Primary & Secondary combustion chambers and smoke filter chamber. Batch load 
on the bottom of chamber. Incinerator PLC panel control suit for local operation.

WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  

Items/Model

TS100M

Principle

Medical Waste Incineration

Burn Rate

Average 50-100 kg/hour

Feed Capacity

Average 100kg

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

1.0Kw

Oil Consumption (kg/hour)

Average 20.4

Natural Gas Consumption (m3n/hour)

Average 24.5

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

250L

Feed Door

70x55cm

Chimney

6 or 8 Meter(as order confirm)

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

270x160x230cm(without chimney)


Basic Plan design to Provide Overall plant layout. With Feed chamber/ charging, Primary Combustion Chamber. 
Secondary Combustion Chamber. Particulate Scrubbers, Acid Gas Scrubbers, The stack/ chimney.
Fuel oil tank storage should be   Mild steel 1000 liters capacity
Chimney Height should be of 10 meters above ground level.
Housing facility with one waste storage room
Adaptability to incineration: Solid waste ,liquid, colloid, and gas can be incinerated simultaneously .

Applicabale material – sludge waste, oily sludge, industrial waste, PVC material, municipal waste, and so on.
Operating temperature- primary 750c/secondary 1050c
fuel type- heavy oil
Electricity -400V/50Hz or 220v/2phase Expansion mode-Linear free expansion at both ends.
Provide Housing designs with adequate cross ventilation

Chamber (Afterburner Maximum exit temperature should not be less than 1100oC
Primary Combustion Chamber Minimum exit temperature should not be less than 850oC
Secondary Combustion Maximum exit temperature should be not less than 1100oC