Incineration is the most obvious solution for total destruction of municipal waste, avoiding
all the direct and indirect risks associated with other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same
place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level.
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity(Average) | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Secondary Combustion Chamber (After burner)
Heavy-duty steel casing
High quality refractory lining and insulation
1 x oil burner
Should be fitted with burners that use low sulphur fuel.
Ensure secondary air supply is controlled.
Ensure residence time is not less than two seconds.
Ensure that the gas temperature as measured against the inside wall in the secondary chamber
Ensure the emitted oxygen content of the emitted gases is not less than 11%
Ensure both primary and secondary combustion temperatures are maintained until all waste is completely combusted.
The chimney should have a minimum height of 10 meters above ground level and clear the
The chimney should be visible to the operator from the feeding area
Low running and maintenance costs
Fully Automatic and simple to operate control panel
Afterburner Preheat
Incineration Temperatures in Excess of 900 degrees C
3 mm Steel Casing and Fully insulated
Dense Refractory Concrete Lining Rated to 1400 degrees C
Solid Hearth to Allow Maximum Burnout
Large Top Opening Lid For Easy Loading
Stainless Steel Flue as standard
12 Months or 1000 hours Warranty.
Optional Stainless Steel Casing
Heat Recovery System option