Incinerator Model YD-150, Overview

This model is middle-scale waste incineration equipment for middle waste output. 
Construction is dual/double combustion chamber with 02 units oil burner, batch load 
incineration equipment. Waste feed chamber is 1500Liters (1.5m3, YD-150). Primary & 
Secondary combustion chambers and included mix-combustion chamber, smoke filter 
chamber and Refractory Concrete chamber. Batch load on the bottom of chamber. Incinerator panel control suit for local operation.

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  

Model

YD-150

Burning Rate

Average 150 kgs/hour

Feed Capacity

Average 300 kgs

P日imary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.03Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

17--36 kg/hour

Gas Consumption (Natural Gas)

11--36.7 m3/hour

Internal Dimensions

150 x 100 x 96cm (primary chamber)

External Dimensions

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

7000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800℃–-1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98%

Waste Lower Calorific Power

3000Kcal

Categories:

Tags:

Comments are closed

www.waste-incinerator.net