Incineration is the only method providing complete destruction and neutralization of 

the medical waste ideally at the source. For developing country and regions, we support 

cheap cost budget customer to purchase the small scale incinerator, with basic function, 

burning rate 10kgs to 50kgs per hour capacity, single combustion chamber and 

three combustion chambers incinerator. It’s good idea for small clinic, small hospital, etc.


WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  

Equipment Technical Specifications

Model

YD-10

Picture

Feed Capacity

Average 20 kgs per feed

Burning Rate

Average 15 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Power

0.5Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

5.4-12.6 Kgs/Hour

External Dimensions

100 x 100 x 160cm (mainbody)

Internal Dimensions

50 x 50 x 80cm(Primary Chamber)

Waste combustion chamber

200Liters

Post Combustion Chamber

100Liters

Oil Tank Capacity

50 Liters

Door Opening

35 x 35cm

Chimney

3.0M

Gross Weight

1000kgs

Chamber Material

Refractory Concrete

Max. Heat Value

126,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

13500C

Residency time

0.5 Sec.

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal