This model is small-scale animal cremation equipment for small pets and animals. 
Construction is dual/double combustion chamber with 02 units oil/gas burner, 
batch load incineration equipment. Animal feed chamber is 360Liters (Model: A360). 
Primary & Secondary combustion chambers and included mix-combustion chamber, 
smoke filter chamber with firebrick and Refractory Concrete chamber(as quotation detail)
Batch load on the bottom of chamber. Incinerator panel control suit for local operation.

Model

A360

Picture

Burning Rate

Average 10 kgs/hour

Feed Capacity

Average 20 kgs/feed

Primary Combustion Chamber

360 Liters

Secondary Combustion Chamber

200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.59Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 13 kg/hour

Gas Consumption (Natural Gas)

Average 16 m3/hour

Internal Dimensions

100 x 60 x 60cm (primary chamber)

External Dimensions

145 x 90 x 260cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

200 Liters

Door Opening

48 x 60cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

2600 kgs

Operation Technical Specifications

Primary Chamber Temperature

800-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal


Control Panel C Burner control, timer control, integral fan timer control, temperature monitoring with 4 digit display for 
primary and secondary chambers. Thermostatic control device for burner control.
Ancillaries C self-contained diesel generator with integral fuel tank and pipework. Operating and maintenance manuals, 
maintenance kit with normal consumable spares for 6 months operation.
Incinerator should have two (2) chambers: primary chamber with five (5) burners to incinerate materials and the secondary 
chamber with two (2) burners to incinerate exhaust gases.
The main body of the incinerator shall be stainless steel and the outside insulation thickness of not less than 7 mm made from 
zinc or phosphate for temperature insulation
The main gate of the Incinerator should be 150 mm thick and strength not less than 170 kg/m3. The door should be automatic with remote to operate.
The Incinerator should be designed in accordance of the environmental regulation followed in country of  origin or  as per  Saudi Arabian PME Regulations.
The incinerator should have fuel storage with capacity of 1000 liter.
The incinerator shall have the capacity to operate with temperature up to 1300 OC in the primary chamber and it can 
remove the residual while the incinerator is in operation
The inside body of the incinerator should have insulation layer made of calcium with thickness of 50 mm while the thickness 
of the internal surface should be 100 mm in order to stand with 1300 OC.
All the supporting braces of the incinerator shall be installed on stainless steel.
The gap between the internal and external body shall be filled with the special insulation material.
The exhaust shall not stay more than two (2) seconds in the secondary chamber and this chamber shall be built with high density of ceramic oasis.
There should be a stack with four (4) meter from the top surface of the incinerator and can be removed and installed.
The incinerator shall have control device for exhaust gases so that the emission shall meet the PME source standards
The power supply should be 220 C 380 Volts, 60 Hz. and the incinerator shall be provided with control panel showing the following:
Mobile medical wasteincinerator Capacity: 20 C 30 KG/H
Primarychambertemperature900C1100C Secondarychambertemperatureabove900C
Flue gas treatment based on multi pollutants control ap- proach to remove hazardous content of the combustion gasses
Fuel: Diesel

Categories: