Incinerator Model YD-150, Overview

This model is middle-scale waste incineration equipment for middle waste output. 
Construction is dual/double combustion chamber with 02 units oil burner, batch load 
incineration equipment. Waste feed chamber is 1500Liters (1.5m3, YD-150). Primary & 
Secondary combustion chambers and included mix-combustion chamber, smoke filter 
chamber and Refractory Concrete chamber. Batch load on the bottom of chamber. Incinerator panel control suit for local operation.

WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  

Model

YD-150

Burning Rate

Average 150 kgs/hour

Feed Capacity

Average 300 kgs

Pimary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.03Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

17--36 kg/hour

Gas Consumption (Natural Gas)

11--36.7 m3/hour

Internal Dimensions

150 x 100 x 96cm (primary chamber)

External Dimensions

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

7000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal